F A H U – A H U – H V A C – FOR SHISHA CAFE DXB +971-55-687-3050 PAK +92-330-687-3050

[vc_row][vc_column][vc_text_separator title=”SHISHA SMOKING AREA AS PER DUBAI MUNCIPALITY” color=”black” border_width=”2″][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_single_image image=”3966″ img_size=”800X750″ alignment=”center”][/vc_column][vc_column width=”1/3″][vc_single_image image=”3965″ img_size=”800X750″ alignment=”center”][vc_empty_space][vc_separator][vc_empty_space][/vc_column][vc_column width=”1/3″][vc_single_image image=”3970″ img_size=”800X750″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]WE ARE AMONG THE MOST TRUSTED SUPPLIERS AND EXPORTERS OF INDOOR CEILING MOUNTED AIR HANDLING UNITS EUROPEAN TECHNOLOGY. THE CEILING MOUNTED AIR HANDLING UNITS OFFERED BY US ARE OF HIGH QUALITY AND MADE USING SUPERIOR QUALITY RAW MATERIALS SO AS TO PROVIDE OUR CUSTOMERS WITH THE BEST PRODUCTS AVAILABLE IN THE SHISHA CAFÉ SMOKING INDUSTRY

CAPACITY RANGE: 1000 cfm TO 8000 cfm

APPLICATIONS: SHOPPING MALL RESTAURANT SHISHA CAFE

FEATURES:  COMPACT LOW HEIGHT WITH / MULTI CENTRIFUGAL FAN DIRECT DRIVEN SPECIAL DESIGN FOR MIDDLE EAST WEATHER AND TEMPERATURE DOUBLE SKIN UNIT WITH ALUMINUM PROFILE, MULTI FUNCTIONAL HEAT WHEEL RECOVERY FUNCTIONS, EXCELLENT THERMAL INSULATION

RANGE: SUSPENDED ON THE CEILING / DUCT TYPE FLOOR TYPE[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”3963″ img_size=”500X250″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][vc_zigzag][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/3″][vc_single_image image=”3967″ img_size=”800X750″ alignment=”center”][/vc_column][vc_column width=”1/3″][vc_single_image image=”3969″ img_size=”800X750″ alignment=”center”][/vc_column][vc_column width=”1/3″][vc_single_image image=”3971″ img_size=”800X750″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_empty_space][vc_zigzag][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column][vc_single_image image=”4210″ img_size=”full” alignment=”center”][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column][vc_single_image image=”4211″ img_size=”full” alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

CEILING TYPE AHU

[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]

CHARACTERISTICS OF CEILING AHU UNITS

A: good performance in mechanical strength, light in weight, corrosion resistance, beautiful shape and accurate size.

B: flexible assemblage, very convenient to install, remove and maintenance. Also, it has longer service life than steel structure.[/vc_column_text][vc_single_image image=”4225″ img_size=”medium” alignment=”center”][/vc_column][vc_column width=”1/2″][vc_single_image image=”4222″ img_size=”850X600″ alignment=”center”][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_single_image image=”4224″ img_size=”500X400″ alignment=”center”][/vc_column][vc_column width=”1/2″][vc_column_text]Panel structure:

A: the panel is formed by two layers of coloured steel plates. Filler between the layers is high-density polyurethane or polystyrene, which has a better performance in thermal isolation than other materials like glass wool. No thermal bridge will be produced while working in all weather or working conditions.

 

B: panels are fixed in a special way, with sealing material to strengthen its thermal and air resistance. This structure has the best performance in thermal isolation, noise reduction and intensity, so it can be used in places require high quality of air.[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]Heat exchanger and water dish

Adopt high quality copper tube aluminium fin structure with φ7 and φ9.52 copper; One step shaping.

Fin punching double flanging, sine corrugated, window aluminium fin with small water resistance and air resistance.

The testing pressure is above 2MPa to keep running under 1.6MPa.

The water dish is drainage slope. One step shaping with painting. It is high strength, no leakage, anti-corrosion.

 

Fan, electrical motor:

A: unit adopts centrifugal fan with both air inlet. The fan runs smoothly in the rigorous static and dynamic balance test.

B: With ball bearings sealed, and functions of pre-lubricating, self-aligning, self-locking, automatic thrust, etc., the fan is maintenance-free in normal use.

C: Fans of a small model unit are driven directly by external sub-motor, no belt, and easy to maintain.

 

Filter

 

There are primary efficiency filter, high and medium efficiency filter according to requirement. Generally it is primary efficiency filter.

Primary efficiency filter is plate structure. The filter frame is gal. press. Filter efficiency G3 (weight efficiency≥60%);Primary resistance 75Pa.Final resistance 150Pa;Filter efficiency F5;Medium efficiency filter efficiency can be reached F8.[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]Production equipment:

① High speed fin production line 4 sets;

②High precision multi-station CNC turret punch press 2 sets,normal punch press 10sets;

③Laser cutting machine 2sets, CNC hydraulic bending machine 4 sets, shearing machine 4 sets

④Vertical expansion tube machine 2 sets

⑤ Auto welding machine;

⑥Programmable automatic bending machine 4 sets;

⑦Frame shape machine 2sets;

⑧Polyurethane foaming machine 2 sets;[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”4223″ img_size=”LARGE” alignment=”center”][vc_single_image image=”4223″ img_size=”850×600″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

AIR HANDLING UNIT

[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]AHU (air handling unit) covers vertical (air volume from 2000 ~ 60000m3 /h), horizontal (wind increased from 2000 ~ 60000m3/h), and ceiling-type (air volume from 1000 ~ 16000m3/h) three series of air-handling unit to meet customers’ need of cooling, heating, humidification, dehumidification and so on. It is widely applied in hotels, theaters, shopping malls, office buildings and a variety of places requires comfortable environment. It also can be used in electronics, chemical, medical, pharmaceutical, cigarettes, food, light engineering and other industrial buildings.[/vc_column_text][vc_empty_space][/vc_column][vc_column width=”1/2″][vc_single_image image=”4233″ img_size=”850X600″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

CHARACTERISTICS OF AHU UNITS

Frame structure: aluminum framework structure is adopted, which is made of high-strength aluminum alloy. Each corner of the framework is made of special castings, allowing the section bar to plug into it. This structure has the following features:

A: good performance in mechanical strength, light in weight, corrosion resistance, beautiful shape and accurate size.

B: flexible assemblage, very convenient to install, remove and maintenance. Also, it has longer service life than steel structure.

Panel structure: A: the panel is formed by two layers of colored steel plates. Filler between the layers is high-density polyurethane or polystyrene, which has a better performance in thermal isolation than other materials like glass wool. No thermal bridge will be produced while working in all weather or working conditions.

B: panels are fixed in a special way, with sealing material to strengthen its thermal and air resistance. This structure has the best performance in thermal isolation, noise reduction and intensity, so it can be used in places require high quality of air.

Fan, electrical motor: A: unit adopts centrifugal fan with both air inlet. The fan runs smoothly in the rigorous static and dynamic balance test.

B: With ball bearings sealed, and functions of pre-lubricating, self-aligning, self-locking, automatic thrust, etc., the fan is maintenance-free in normal use.

C: fans of a small model unit are driven directly by external sub-motor, no belt, and easy to maintain.

Filter: unit filter is coarse plate. Filter material is cleanable convex Nylon net.

Cooler: the selected parameters of surface air cooler are designed by CAD/coi1 software. A standard cooler normally has copper pipes of φ6. It is tightened by an overall rise up of brass strung by corrugated aluminum fin tubes. Staggered copper pipes have good heat transfer performance, low airflow resistance and superior corrosion resistance, ensuring the cooler has a higher heat transfer coefficient and a longer life.[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

FRESH AIR EXCHANGER

[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]Plate-fin heat exchanger is a kind of  static type heat exchanger for air to air direct exchange, it does not need heat transfer through the intermediate medium.There is no rotation system, therefore, static type plate-fin heat exchanger (also called stationary heat exchanger) is a kind of ideal energy recovery equipment.Static type plate-fin heat exchanger can be heat recovery when there is the two strands of airflow temperature and vapor pressure difference at both sides.[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”4236″ img_size=”850X600″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

Working principles:

① Humidity exchanger by  moisture vapor pressure difference at both sides.

② The water vaporof high moisture side is absorbed by hygroscopic agent to the low humidity side by the capillary effect of the paper fibers.

 

Plate-fin heat collector:
A, Static type heat exchanger: in order to decorate air flow channel and reduce the equipment volume, the small and medium-sized fresh air exchagner adopt flat cross stationary type heat exchanger.Its working principle: the movement direction of cold and hot air is perpendicular. The air flow is turbulent boundary layer and the convective heat transfer properties in the heat exchanger with high heat exchange efficiency.
B, Sensible heat exchanger and whole heat exchanger: Sensible heat exchanger made of aluminum foil material with high temperature conductivity and long service life; It is suitable for indoor and outdoor big temperature difference and small humidity difference areas.The whole heat exchanger made of special fibers by a special process of paper;this kind of material has high moisture permeability, good air tightness, tear resistance, ageing resistance characteristics.Whole heat exchanger is suitable for indoor and outdoor  small temperature difference and large humidity.[/vc_column_text][vc_empty_space][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_column_text]Features

1.Double air exchange for indoor and outdoor.

2.Filter treatment:it meets the construction regulations to avoid the dust into indoor.

  1. High efficiency and saving energy:Inside static heat exchanger;the heat exchange efficiency is more than 70%.The cold and heat load has not been effected by fresh air,so it can be improved the efficiency and saved energy.

4.Easy installation:It is whole structure to easy connect.

5.Safe and reliable:There is no other running parts except fan.So it is low noise and safe.

6.Low cost:it does not need the operation room.There is heat energy recovery system to reduce energy consumption up to 30%.

  1. Fine production: adopt high quality steel, environmental protection material, aluminum alloy frame.

[/vc_column_text][/vc_column][vc_column width=”1/2″][vc_single_image image=”4237″ img_size=”850X600″ alignment=”center”][/vc_column][/vc_row][vc_row][vc_column width=”1/2″][vc_single_image image=”4238″ img_size=”850X600″ alignment=”center”][/vc_column][vc_column width=”1/2″][vc_column_text]Filter

The plate-fin heat recovery collector can be used for many place. So it need primary filter to filter the dust. Its filter class is G4.

 

Condensate water dish

In north of cold area, if it is sensible  heat type, it will cause cold water, so it need the condensate water dish. But it does not need it for whole heat type

Fan

Small and medium-sized fresh air ventilation adopt outer type and high efficiency and low noise centrifugal fan. All fan impellers passed  dynamic balance test; Impeller bearing use automatic bearing without maintenance. It had added anti-high temperature grease for long service life. Low noise is low, and aerodynamic performance is good; The connection structure of the impeller and volute make to easy replace the wheel bearings and motor during maintenance.[/vc_column_text][/vc_column][/vc_row][vc_row][vc_column][vc_column_text]

Construction

It is module design to reduce the production time.

Framework is composed of closed aluminum profile, cross section shape is hole, the casing material is color steel plate with the folding resistance, good corrosion resistance, corrosion resistance, anti-acid, alkali and salt. And it will not fade 15 years. Inside and outer fill the delta = 30 mm thick polystyrene or polyurethane thermal insulation material to improve the stiffness of the shell and anti-corrosion ability;  It has a good ability of insulation and airtight persistent. The colour of colour steel plate is pearl white.

Inside sheet metal parts are made of galvanized steel. Adopt sealing strip seals for the joint with resistance to high temperatures (+ 90 ℃) and low temperature (60 ℃).And it is long service life.[/vc_column_text][/vc_column][/vc_row]

Call Now Button